PUBLIKATIONSSERVER

50/60 Hz Power Grid Noise as a Skin Contact Measure of Textile ECG Electrodes

K. Tuvshinbayar, G. Ehrmann, A. Ehrmann, Textiles 2 (2022) 265–274.

Download
OA 4.04 MB
Artikel | Veröffentlicht | Englisch
Autor*in
Abstract
The electrocardiogram (ECG) is one of the most commonly measured biosignals. In particular, textile electrodes allow for the measuring of long-term ECG without skin irritation or other discomforts for the patient. Such textile electrodes, however, usually suffer from insufficient or unreliable skin contact. Thus, developing textile electrodes is impeded by the often-complicated differentiation between signal artifacts due to moving and breathing and artifacts related to unreliable skin contact. Here, we suggest a simple method of using 50/60 Hz power grid noise to evaluate the skin contact of different textile electrodes in comparison with commercial glued electrodes. We use this method to show the drying of wetted skin under an embroidered electrode as well as sweating of the originally dry skin under a coated electrode with high water vapor resistance.
Erscheinungsjahr
Zeitschriftentitel
Textiles
Band
2
Zeitschriftennummer
2
Seite
265-274
eISSN
FH-PUB-ID

Zitieren

Tuvshinbayar, Khorolsuren ; Ehrmann, Guido ; Ehrmann, Andrea: 50/60 Hz Power Grid Noise as a Skin Contact Measure of Textile ECG Electrodes. In: Textiles Bd. 2, MDPI AG (2022), Nr. 2, S. 265–274
Tuvshinbayar K, Ehrmann G, Ehrmann A. 50/60 Hz Power Grid Noise as a Skin Contact Measure of Textile ECG Electrodes. Textiles. 2022;2(2):265-274. doi:10.3390/textiles2020014
Tuvshinbayar, K., Ehrmann, G., & Ehrmann, A. (2022). 50/60 Hz Power Grid Noise as a Skin Contact Measure of Textile ECG Electrodes. Textiles, 2(2), 265–274. https://doi.org/10.3390/textiles2020014
@article{Tuvshinbayar_Ehrmann_Ehrmann_2022, title={50/60 Hz Power Grid Noise as a Skin Contact Measure of Textile ECG Electrodes}, volume={2}, DOI={10.3390/textiles2020014}, number={2}, journal={Textiles}, publisher={MDPI AG}, author={Tuvshinbayar, Khorolsuren and Ehrmann, Guido and Ehrmann, Andrea}, year={2022}, pages={265–274} }
Tuvshinbayar, Khorolsuren, Guido Ehrmann, and Andrea Ehrmann. “50/60 Hz Power Grid Noise as a Skin Contact Measure of Textile ECG Electrodes.” Textiles 2, no. 2 (2022): 265–74. https://doi.org/10.3390/textiles2020014.
K. Tuvshinbayar, G. Ehrmann, and A. Ehrmann, “50/60 Hz Power Grid Noise as a Skin Contact Measure of Textile ECG Electrodes,” Textiles, vol. 2, no. 2, pp. 265–274, 2022.
Tuvshinbayar, Khorolsuren, et al. “50/60 Hz Power Grid Noise as a Skin Contact Measure of Textile ECG Electrodes.” Textiles, vol. 2, no. 2, MDPI AG, 2022, pp. 265–74, doi:10.3390/textiles2020014.
Alle Dateien verfügbar unter der/den folgenden Lizenz(en):
Creative Commons Namensnennung 4.0 International Public License (CC-BY 4.0):
Volltext(e)
Access Level
OA Open Access
Zuletzt Hochgeladen
2022-07-14T17:42:16Z


Link(s) zu Volltext(en)
Access Level
Restricted Closed Access

Export

Markierte Publikationen

Open Data LibreCat

Suchen in

Google Scholar